TurboNOx
TurboSonic Nitrogen Oxide (NOx) Control Systems are Designed and Custom Manufactured to Meet Your Needs
The TurboNOx Advantage
TurboSonic NOx control systems feature patented, wear and plug-resistant Turbotak air-atomized nozzle technology for controlled drop size and spray coverage. High efficiency Turbotak injectors provide superior performance and range: up to 90-95% reaction efficiency and 60-80% removal efficiency.
The NOx Reduction Process
Selective Non-catalytic Reduction (SNCR) is a proven method for controlling cement kiln NOx emissions by injecting an ammonia or urea solution into the gas stream, where it reacts with nitrogen oxides to produce harmless by-products.
Ammonia reaction - optimal temperature 1600-2100ºF (870-1150ºC)
2NH3 + 2NO + ½ O2 → 2N2 + 3H2O
Urea reaction - optimal temperature around 1000ºC
CO(NH2)2 + 2NO + ½ O2 → 2 N2 + CO2 + 2H2O
TurboSonic Offers a Complete Equipment Scope of Supply for SNCR as well as Ammonia Feed and Injection Equipment for Selective Catalytic Reduction (SCR) Systems
- CFD and physical flow modeling
- System design and engineering
- Nozzles/lances
- Unloading stations/handling equipment
- Tanks, scrubbers
- Pumping/transfer skids
- Mixing/dilution controls
- Headers
- Metering control skids
- Installation/startup
- Technical service and support